Sign In | Join Free | My himfr.com
himfr.com

ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Verified Supplier

4 Years

Home > Oxygen Gas Sensor >

AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air from wholesalers
     
    Buy cheap AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air from wholesalers
    • Buy cheap AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air from wholesalers
    • Buy cheap AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air from wholesalers

    AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air

    Ask Lasest Price
    Model Number : AO-06
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000pcs
    Delivery Time : 3-5work days
    • Product Details
    • Company Profile

    AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air


    AO-06 Electrochemical Oxygen sensor


    Product Brief:
    The AO-06 oxygen sensor is an electrochemical sensor specifically designed for measuring oxygen concentration in medical equipment. Its interface model is 5520257-2. It adopts a molded main body design and features rapid response and long service life. It can be replaced domestically, helping customers reduce costs at the same time
    It provides outstanding quality.
    The difference between this sensor and the AO-07 oxygen sensor lies in the different pin definitions.
    Full-range linear output
    The operation does not require an external power supply
    Temperature compensation
    Quick response
    Accurate and reliable
    Strong anti-interference ability
    Application scope:
    The AO-06 oxygen sensor does not require an external power supply when in operation. It has undergone professional and accurate product calibration and temperature compensation before leaving the factory. It can be used as the sensing component of oxygen analyzers, such as oxygen generator control devices, medical ventilators, anesthesia equipment, incubators, etc.
    Installation requirements:
    When installing the sensor, it should be tightened by hand and ensure good air tightness. Do not use wrenches or similar mechanical auxiliary tools to prevent the sensor thread from being damaged due to excessive force.
    Storage and Usage:
    The AO-06 oxygen sensor should be protected from exposure to high-concentration organic solvent vapors during storage, installation and operation. When using sensors with printed circuit boards (PCBS), the PCB should be cleaned with a degreaser before installing the sensor to prevent impurities such as rosin from evaporating and condensing, which could clog the breathable membrane of the oxygen sensor. Organic solvents are prohibited on the sensor housing as they may cause the plastic to crack.
    Cleaning"
    If the sensor housing is contaminated, the sensor can be cleaned with distilled water and allowed to dry naturally. Steam cannot be used on the sensor Steam sterilization or prolonged exposure of the sensor to an environment containing chemicals such as ethylene oxide and hydrogen peroxide.
    Temperature compensation< 2% O2 equivalent (0-40 ℃)
    Load resistance≥10 kΩ
    InterfaceP/N 5520257-2
    Shell materialWhite ABS
    WeightApproximately 40 grams
    Operating temperature range0 to 50 ℃
    Working pressure range0.5-2.0 bar
    Working humidity range0-99% RH (no condensation)
    Service life1.5× 106% O2 hours (at 20 ℃) 3 0.8× 106% O2 hours (40 ℃)
    Warranty period13 months from the date of shipment
    Measurement range0 to 100%

    AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air

    Quality AO-06 Electrochemical Oxygen Sensor Response Time 15 Seconds Output Voltage 9-13 mV in Air for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)