Sign In | Join Free | My himfr.com
himfr.com

ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Verified Supplier

4 Years

Home > Oxygen Gas Sensor >

1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector from wholesalers
     
    Buy cheap 1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector from wholesalers
    • Buy cheap 1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector from wholesalers
    • Buy cheap 1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector from wholesalers
    • Buy cheap 1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector from wholesalers

    1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector

    Ask Lasest Price
    Brand Name : CITY
    Model Number : 1O2 AAW85-07WA-CIT
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 311/pcs/pre
    Delivery Time : 3-5work days
    • Product Details
    • Company Profile

    1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector

    Product Description:

    1O2 AAW85-07WA-CIT Oxygen (O2) Simulated Gas Sensor For Oxygen Detector


    Features:

    The purpose of this document is to present the performance specification of the 1series 1O2 oxygen gas sensor.

    This document should be used in conjunction with the 1O2 Characterisation Note, the Operating Principles (OP09), and the Product Safety Datasheet (PSDS 5).

    For guidance on sensor performance outside of these limits, please refer to the 1O2 Characterisation Note.

    Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP09).

    Poisoning

    Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided during 1) storage, 2) fitting into instruments and 3) operation.

    When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted.

    Do not glue directly on or near the sensor as the solvent may cause crazing of the plastic.


    Specifications:

    T50 Response Time*

    < 10 seconds (@ 20°C)

    < 15 seconds (@ -40°C to +60°C)

    T90 Response Time*Typically < 15 seconds
    R90 Recovery Time*< 45 seconds (@ -20°C to +60°C)
    R95 Recovery Time*< 60 seconds
    Recommended Load Resistor10 W

    1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector


    Quality 1O2 PCB Replacement Oxygen Gas Sensor AAW85-07WA-CIT Simulated For Oxygen Detector for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)